Table 2 Overall performances of each application

From: Artificial neural network, genetic algorithm, and logistic regression applications for predicting renal colic in emergency settings

Application

Sensitivity

Specificity

PLR

NLR

AUC

ANN

94.9

78.4

4.4

0.06

0.867

GA rule 1

67.6

76.47

2.9

0.42

0.720

GA rule 2

56.8

86.3

4.1

0.5

0.715

Logistic regression

95.5

47.1

1.8

0.09

0.713