Skip to main content

Table 2 The primary outcome on Little Anne and Push Heart

From: Comparison of quality of chest compressions during training of laypersons using Push Heart and Little Anne manikins using blinded CPRcards

 

Little Anne

Push Heart

p value

Compression depth (mm)

41.5 (33.0–48.0)

38.0 (31.8–41.0)

0.0664

Compression rate (cpm)

105.0 (101.0–109.5)

103.0 (101.0–105.5)

0.2429

Adequate depth (%)

5.5 (0–42.5)

1.5 (0.0–7.5)

0.0498*

Adequate rate (%)

79.5 (69.0–90.3)

84.0 (67.3–93.3)

0.4575

  1. Median(IQR), Wilcoxon test, two-tails
  2. *p < 0.05 significant