Table 1 Sensitivity and specificity for bone scans, MR examination and CT scans

From: Current methods of diagnosis and treatment of scaphoid fractures

 

Sensitivity (%)

Specificity (%)

Bone scan [19]

100 (83-100)

90 (81-96)

MR examination [19]

80 (56-94)

100 (96-100)

CT [48]

93 (83-98)

99 (96-100)